• Type K thermocouple temperature meter
  • rtd temperature meter
  • temperature display unit
  • Thermocouple temperature meter
  • type k thermocouple meter

Thermocouple RTD Temperature Meter

Model: BRT TM1

BRT TM1 Universal input thermocouple RTD temperature meter is an accurate panel-mounted PT100, Cu50 thermocouple sensor signal display and measuring meter. Its input sensor signal is selectable, unit display is settable. Have cold-junction compensation setting.

Main Features
● RTD thermocouple sensor signal input.
● 0.25% F.S. (RTD), 0.5% F.S. (TC)accuracy grade.
● Have manual cold-junction compensation setting.
● Display unit ℃ can be set into hide status.
● Sampling rate: 2-3 times per second.

BRT TM1 Universal input thermocouple RTD temperature meter supports thermocouple sensors type K, J, B, S, T, RTD PT100, Cu100, Cu50, W5RE, W3RE sensor signal input.  Its input sensor signal is processed by the precision MCU embedded. Inside the temperature meters, there are cold-junction compensation circuit for thermocouple sensor, 15Ω compensation resistance for PT100 sensor signal. Its input sensor type is selectable through the DIP switching button. Its display panel is 5 bytes 0.56inch LED tube, its display unit and ambient temperature calibration can be set through setting buttons inside. It has standard panel-mounted shell, wide range power supply, polarity-reverse protection, very convenient to use or do integration.

Main Applications
● 3-wire PT100 sensor signal display.
● Thermocouple sensor signal display and data acquisition.
● Industrial temperature signal monitoring.
● Industrial automatic equipment signal controlling & monitoring.
● Boiler, furnace, heater, other temperature signal monitoring.

Typical wiring circuit

RTD PT100 sensor input wiring

RTD PT100 sensor input wiring

Thermocouple sensor signal input wiring

Thermocouple sensor signal input wiring

Dimension

Thermocouple RTD temperature meter size

Thermocouple RTD temperature meter size

The product detailed specifications below:

SpecsValue
Input sensor type 3-wire PT100, Cu50, Cu100, thermocouple type K, J, B, T, N, R, S, E, W5RE- W26RE, W3RE-W25RE
Measuring accuracy0.5%F.S. TYP, ±0.5℃, cold-junction compensation is not included.
Sampling rate2-3 times/second
Operating power supply5-12VDC (<100mA)
RTD linear compensation≤15Ω
TC cold-junction compensation0℃- 50℃, compensation accuracy 2℃, only for thermocouple sensor signal input
Protection circuitinput sensor breaking indication, polarity-reverse connection protection.
Display5 bytes, 0.56inch LED tube, unit ℃ is settable
Wiring mode screw wiring terminal block
Panel installation cut-out size76.5×39.5(L x W)
Operating temperature-20-+70℃
External shell size79x43x26 (L x W x H)

Buy it online (click): RTD Thermocouple Temperature Meter