BRT IAB Isolated 0-20mA 4-20mA 0-10V 0-5V signal conditioner is a slim size precision current voltage signal conditioning and isolation module. It accepts industrial analog signal 0-20mA, 4-20mA , 0-5V, 0-10V, 1-5V, etc input, and converts input signal into standard 0-5V, 0-10V, 4-20mA, 0-20mA, etc in linearity. Its isolation voltage is 2.5KV. Operating power supply input is 24VDC.

Main Features
● 0.1% F.S. high accuracy linear conversion.
● 18-32VDC (24VDC) operating power supply.
● Slim shell with pluggable wiring terminals.
● 2.5KV isolation among input, output, power.
● 0-20mA, 4-20mA, 0-5V, 0-10V, etc input & output.

HIC IAB Isolated current voltage signal conditioner converter is a slim size energy saving current to voltage, voltage to current, voltage to voltage, current to current signal isolated conversion and amplification module. It accepts 2-wire 4-20mA, 3-wire 4-20ma, 4-20ma current source signal and 0-5V, 0-10V voltage signal input, and converts current signal input into standard 0-5V, 0-10V, 4-20mA, etc after filtering noise and ripple through advanced isolation technique. Its output signal is used as the input of PLC, DCS, meters and other controlling devices for signal controlling, data acquisition and transmission. That isolated signal converter can withstand 2.5KV voltage shock among input, output, auxiliary power supply. It is a low cost high isolation precision signal converter module. It is widely used in 4-20mA to 0-5V, 4-20mA to 0-10V, 4-20mA to 4-20mA, 0-5V to 4-20mA, 0-10V to 4-20mA conversion, 0-10V to 0-10v isolation, 0-5V to 0-5V isolation, etc. applications.

Typical Applications

● 0-20mA 4-20mA, 0-5V, 0-10V, 1-5V,etc signal isolated conversion.
● Industrial process controlling signal noise filtering.
● Industrial sensor signal data acquisition and controlling.
● PLC, DCS, DAS system signal conversion and transmission.
● Valves, level sensors, pressure transmitters, etc. sensor signal conversion.

4-20mA to 0-10V signal conditioner

DIN Rail-mounted slim size shell

4-20mA to 0-5v signal conditioner wiring

Wiring method

Typical Wiring Circuits

4-20mA to 0-5V 4-20mA wiring

4-20mA to 0-5V 4-20mA wiring

0-5V 0-10V input wiring circuit

0-5V 0-10V input wiring circuit

The product detailed specifications below:

SpecsValue
Input signal4-20mA, 0-20mA, 0-5V, 0-10V, etc
Input to output channels1-input 1-output
Max. current input25mA
Distribution power≥21VDC
Input impedance≤25Ω
Output signal4-20mA, 0-20mA, 0-5V, 0-10V, 1-5V, etc
Output currentMax. 25mA
Output load resistanceRL ≤800Ω, output current signal; RL≥1MΩ, output voltage signal.
Output ripple≤10mVP-P
Auxiliary power SupplyRated 24VDC, 18-30VDC wide range.
Current consumption≤39mA (1-input 1-output, 24V power supply, 20mA output, 550Ω load.);
Accuracy±0.1% F.S.
Temperature drift≤±1uA/10℃, TYP.
Isolation voltage2500VAC/1 min among input, output, power supply input.
Insulation resistance≥100MΩ among input, output, auxiliary power supply
Size115x100x12.8mm (WxHxT)
EMC compatibilityIn compliance with IEC61326-1 /GB/T18268.
External shell materialPPO
Operating temperature-20 to +70℃, continuous operating.
Storage temperature-40 to +80℃
Humidity10-90% RH, non-condensation.